Dimensions |
N/A 120×120×25 mm |
Mass |
N/A 370 g |
Frame Material |
N/A Aluminum |
Impeller Material |
N/A Plastics (Flammability: UL94V-1) |
Dielectric Strength |
N/A 50/60Hz 1,500VAC 1minute (between input terminal and frame) |
Dielectric Strength (With Sensor) Between AC input and DC input (Sensor output) |
N/A 50/60Hz 1,000VAC 1minute |
Dielectric Strength (With Sensor) Between AC input and G |
N/A 50/60 Hz 1,500 VAC 1 minute |
Dielectric Strength (With Sensor) Between G and DC input (Sensor output) |
N/A 50/60Hz 1,000VAC 1minute |
Sensor-Purpose Anode Lead Wire Color (+) |
N/A Brown |
Sensor-Purpose Cathode Lead Wire Color (-) |
N/A Black |
Sensor-Purpose Lead Wire Color |
N/A Yellow |
Non-Condensing Storage Temperature |
N/A -30 to +70 ºC |
Operating Voltage Range |
N/A Voltage of each model ±10% |
Rated Voltage |
N/A 100 V |
Frequency |
N/A 50/60 Hz |
Input |
N/A 13.5/12 W |
Current |
N/A 0.16/0.14 A |
Locked Rotor Current |
N/A 0.19/0.17 A |
Rated Speed |
N/A 2,500/2,900 |
Maximum Air Flow |
N/A 1.95/2.3 m³/min68.9/81.3 ft³/min |
Maximum Static Pressure |
N/A 48 /51.9 Pa0.193/0.216 inH2O |
Sound Pressure Level |
N/A 38/41 dBA |
Operating Temperature |
N/A -30 to +60 ºC |
Expected Life at 60ºC |
N/A 25000 hours |